Materiały konferencyjne SEP 2018
XXVII SCHOOL OF UNDERGROUNDMINING 2018 , Cracow, Poland CONDITION FOR USING OF BOLTING SYSTEMS Self-support bolting system do not be used: Coefficient RMR is lower than 41 Water inflow from one instalation borehole is higher than 0.01 dm 3 /min If the coal seam with thickness 1m is in overburden to the distance 5 m from roof of bolting seam Dip of seam is higher than 22° A limitation is also the rule that forbids using of the self-support bolting system in areas with 3rd rockburst risk